Click here to connect us on
Flue Gas Analyzer System (ZSU)
Description:
Continuous monitoring of up to 5 components:
NOx, SO2, CO, CO2, and O2
Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Japanese type approval
Flue Gas Analyzer System (ZSJ)
(Single beam, sample switching system)
Description:
Continuous monitoring of 5 components:
NOx, SO2, CO, CO2, and O2
Ideal for flue gas monitoring in waste incinerators, boilers, and furnaces
Simultaneous and continuous measurement of up to 5 components
Sample switching system ensures zero-point stability
Space-saving design
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Japanese type approval
Flue Gas Analyzer System (ZSU-7)
Continuous monitoring of 7 components:
NOx, SO2, CO, CO2, O2, HCl, and dust
Ideal for environmental monitoring
Space-saving design
All the necessary equipment are housed in a cabinet of 1215 (W) x 700 (D) x 1780 (H) mm size
Less electrical work: signal and power terminals are in one place
Maintenance-free HCl measurement
Japanese type approval (NOx, SO2, CO, O2)
Saves power by 40% compared to conventional models
Flue Gas Analyzer System (ZSS)
Description:
Continuous monitoring of HCl, NH3, CO, CO2, CH4, and O2
Low maintenance
Low operating-cost: with no gas-sampling device and few parts to be replaced
Superior long-term stability
Fast response within 2 seconds
Tolerant to high temperature and high dust
Environment friendly: 80 VA, low power consumption
Analog output for transmittance is available
Compliant with RoHS directive (2011/65/EU)
Double-beam version for CO and O2 measurement available
Aerosol Analyzer (ZSF)
Description:
Real-time, quantitative measurement of aerosol (PM2.5) in the air
Real-time monitoring
Simultaneous and quantitative analysis of particle size, number of particles, and composition
High accuracy ensured by a combination of multiple principles
Easy-to-use touch screen
in-Situ Zirconia Oxygen Analyzer System (ZSB)
Description:
Continuous measurement of O2 in flue gas from industrial boilers or furnaces. Ideal for combustion control
Fast response
Low maintenance
A variety of inputs and outputs
Easy to operate
Double Beam NDIR Gas Analyzer (ZKJ)
Description:
Simultaneous and continuous measurement of up to 5 components among:
NO, SO2, CO2, CO, CH4, N2O, and O2
Ideal for flue gas monitoring in incinerators and industrial furnaces
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
Easy-to-see LCD
Zero drift for 200 ppm range: ≤ ±1% FS per week
Single Beam NDIR Gas Analyzer (ZPA)
Description:
Simultaneous and continuous measurement of up to 5 components among NO, SO2, CO, CO2, CH4, and O2 in incinerators or boilers
Compact and lightweight: 19-inch rack mount
Built-in magnetic O2 sensor or optional galvanic O2 sensor
Optional functions include: atmospheric pressure compensation, RS-485 communication, automatic calibration, alarm output, O2 correction, and more.
Low maintenance
Single Beam NDIR Gas Analyzer (ZPG)
with sample-switching system (low-concentration type)
Description:
Continuous monitoring of low-level CO or CO2 in the air or the air separation facilities
Long-term superior stability: zero drift ±0.5% FS per week
Compact and lightweight: 19-inch rack mount
Continuous measurement of low concentration gas
Built-in magnetic O2 sensor or optional galvanic O2 sensor
Low maintenance
Single Beam NDIR Gas Analyzer (ZRE)
Description:
Simultaneous and continuous measurement of up to 5 components among NO, SO2, CO, CO2, CH4, and O2 in incinerators or boilers
Compact design
Long-term superior stability
Easy-to-see LCD
Optional functions include: auto calibration, concentration alarm, remote range-switching, and more.
Hardly affected by moisture interference
Thermal Conductivity Gas Analyzer (ZAF)
Description:
Ideal for H2, Ar, and He measurement
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
Flameproof Thermal Conductivity Gas Analyzer (ZAFE)
Description:
Ideal for H2, Ar, and He measurement
Easy-to-see LCD
RS-232C communication (option)
Compact, panel mount design
Automatic calibration (option)
Interference compensation (option)
Concentration alarm (option)
Paramagnetic Oxygen Analyzer (ZAJ)
Description:
Fast response within 2 seconds, Tolerant to interference
Non-contact detector with long-term superior stability
Highly sensitive mass flow sensor enables low concentration measurement
Long-life detector with no moving parts
Interference compensation (option)e
Paramagnetic Oxygen Analyzer (ZKG)
Description:
No need for reference gas, Ideal for measuring oxygen in flammable gas
Dumbbell type paramagnetic system requires no reference gas
Suited for oxygen in flammable gas
Interference effect is negligible
Japanese type approval
In-Situ Zirconia Oxygen Analyzer (ZFK8, ZKM1/ZKM2, ZTA)
Description:
In-situ oxygen analysis requires no gas sampling device, Ideal for combustion control in industrial boilers and furnaces
FEATURES:
Easily replaceable zirconia element
Fast response (4 to 7 seconds)
IP66 or IP67 enclosure
Safe design
High safety level:
The converter cuts off the power supply for the detector when detecting a burnout of thermocouple.
The converter also cuts off the power supply at emergency, in response to an external contact input.
The key lock function prevents operational errors
In- Situ Zirconia Oxygen Analyzer (HART Communication) (ZTA ,ZKMA/ZKMB, ZFK8)
Description:
In-situ oxygen analysis requires no gas sampling device. Ideal for combustion control in industrial boilers and furnaces
FEATURES:
HART communication
Easily replaceable zirconia element
Fast response (4 to 7 seconds)
IP66 or IP67 enclosure
Safe design
High safety level
The converter cuts off the power supply for the detector when detecting a burnout of thermocouple.
The converter also cuts off the power supply at emergency, in response to an external contact input.
The key lock function prevents operational errors.
Zirconia Oxygen Analyzer for Hazardous Location (ZKME, ZFKE)
Description:
Fast response + no sampling involved — ideal for combustion management in boilers or furnaces Use of flow guide tube — low maintenance Flameproof design — ideal for oxygen analysis in hazardous areas, for example, petrochemical plants
Easily replaceable zirconia element
Fast response: 4 s to 7 s
Operation available without opening the cover
TIIS and NEPSI flameproof certified
Compact NDIR Gas Analyzer (ZSVF)
Description:
Simultaneous and continuous measurement of up to 5 components among: NOx, SO2, CO, CO2, CH4, and O2 Suited for monitoring of flue gas, combustion gas, biogas, etc.
Continuous measurement for 5 days max.
Separatable structure
A variety of functions: auto calibration, O2-corrected output, averaging, alarm, etc.
You can check the concentration changes of all components at a glance
Easy-to-use interface
You can select a paramagnetic O2 sensor or a galvanic O2 sensor
Portable NDIR Gas Analyzer (ZSVS-2)
Description:
Simultaneous and continuous measurement of up to 4 components: CO, CO2, CH4, O2. Suited for gas monitoring in heat treatment furnaces, plant cultivation, and research-purpose chemical analysis.
Equipped with gas suction pump and membrane filter—no need for gas sampling devic
CP (Carbon Potential) calculation available (option)
A variety of functions: O2-corrected output, averaging, automatic display off, etc.
NDIR Gas Analyzer (ZFG)
Description:
Continuous measurement of CO, CO2, CH4 in heat treatment furnace. Simultaneously and continuously measures concentrations of 2 different gases
Repeatability: ±0.5% FS
CP (Carbon Potential) calculation available (option)
Single-beam system: long-term stability and low maintenance
Simultaneous and continuous measurement of 2 different gases
Compact and lightweight (approx. 5 kg)
Biomass Gas Analyzer (ZPAF)
Description:
Measures H2S, CH4, CO2, and O2 generated in biogas plants
Simultaneous and continuous monitoring of H2S, CH4, CO2, and O2
Compact and lightweight: 19-inch rack mount, 9 kg
Easy-to-see LCD
Optional functions include: automatic calibration, concentration alarm, remote input for switching range, and more.
NDIR Gas Analyzer (3-Compoonent Analyzer) (ZKJ7)
Description:
ZKJ7 is the substitute for the obsoleted model ZRG. Size and terminal allocation are designed same with ZRG for ease of replacement.
Simultaneously and continuously measures up to 3 components among NO, SO2, CO, CO2, CH4, and O2
Hardly affected by interference from other gases
Optional functions include: automatic calibration, O2 correction, averaging, concentration alarm, remote range-switching, and more.
Easy-to-see backlit LCD
NDIR Gas Analyzer (ZPAH, ZPA1)
Description:
ZPAH and ZPA1 are substitutes for the obsoleted model ZRH. Size and terminal allocation are designed same with ZRH for ease of replacement.
Continuously measures SO2, CO, CO2, CH4, or CO+CO2
Hardly affected by interference from other gases
Optional functions include: automatic calibration, remote range-switching, rage identification output, and more.
Easy-to-see backlit LCD
NDIR Gas Analyzer (ZPAJ)
Description:
ZPAJ is a substitute for the obsoleted model ZRJ. Size and terminal allocation are designed same with ZRJ for ease of replacement.
Continuously measures SO2, CO, CO2, CH4, NO, O2
Hardly affected by interference from other gases
Optional functions include: automatic calibration, remote range-switching, rage identification output, and more.
Easy-to-see backlit LCD
Gas Sampling Devices (ZB, ZDL)
Gas extractor: ZBA
Gas cooler: ZBC
Gas aspirator: ZBG
Gas converter: ZDL
Gas dryer: ZBJ
Draining: ZBH
Flowmeter and regulator: ZBD
Valve: ZBF
Gas filter, separator, mist catcher, etc.: ZBB
Standard gas: ZBM
Spool Piece Ultrasonic Flowmeter (FST)
Description:
Three pairs of sensors for accuracy of ±0.2% of rate
High accuracy
Low maintenance
Bubble resistant
Wide temperature range from -40°C to +150°C
Easy-to-operate
IECEx, ATEX, NEPSI, and Japanese ex-proof certificatione
Portable Ultrasonic Flowmeter (FSC)
Description:
Compact and handy
High accuracy ±1.0% of rate and fast response ≤ 1 s
A wide variety of detectors
Tolerant to bubbles
Battery-powered, for 12 hours
Data storage on SD card
USB port for connection with PC
Consumed energy calculation
Printer (option)
Flow velocity profile (option)
Time DELTA-C (FSV)
Description:
Excellent anti-bubble performance.Applicable pipe diameter: 13–6000 mm. Flow transmitter (FSV). Detector (FSS)
High accuracy: 1.0% of rate
Fast response: 0.2 seconds
Compact transmitter: 142 x 170 mm
Excellent anti-bubble performance
Operation available without opening the cover
RS-485 communication (option)
Wide application range
Parameter loader software provided
M-Flow PW (FLR)
Description:
Excellent anti-bubble performance. Compact size transmitter. Applicable pipe diameter: 25–1200 mm.
Flow transmitter: FLR
Detector: FSS
Excellent anti-bubble performance
Standard accuracy: 1.5% of rate (1.0% is also available)
Fast response: 0.2 seconds
Operation available without opening the cover
RS-485 communication (option)
Parameter loader software provided
Extendable detector for pipe size from 50 mm to 1200 mm
Ultrasoinc Flowmeter for AIr (FWD)
Description:
Ideal for compressor control. Applicable pipe diameter: 25–200 mm
No pressure loss = no energy loss
Tolerant to oil and mist - No need for filter such as mist separator
Lithium-ion battery driven version available
Battery life: approx. 10 years
Flow rate conversion
Actual flow rates are converted into those in normal or standard conditions.
Forward/reverse flow measurement
Air leakage detection
FCX-AIII Pressure and Differential Transmitter
Description:
FCX-AIII series transmitters are electronic transmitters which use electrostatic capacitance sensors. They feature compact design, high accuracy, and long-term stability, and offer a variety of diaphragm materials. You can select from: type L housing suited to a vertical pipe, type T housing to horizontal pipe, and direct mount type
Long-term superior stability: ±0.1% for 10 years
Fast response (60 ms)
Field configurator (option)
High temperature/vacuum transmitter with solid technology
Equalizing Valve, Oval Flange (FFN, FFP)
Description:
For the use with differential pressure transmitters
Operating pressure: 16 MPa, 42 MPa
Material Main unit: Stainless steel 316
Mounting bolt: Stainless steel 316L
Gasket: Teflon
Fluid temperature: -40°C to 120°C
Process connection: Rc1/2, Rc1/4, 1/2–14NPT, 1/4–18NPT
Others: Version with pressure pipe is also available
FCX-AIII Series Hand Held Communicator (FXW)
Description:
For communication with transmitters
Display 16-digit, 4-line LCD
Power supply Built-in nickel-cadmium battery (5 hours for full charge)
Battery life Approx. 24 hours (standard specification)
Printer Optional (24-digit printing on thermal paper)
Weight Approx. 500 g (without printer)
Carrying case Optional
Orifice Plate with carrier ring (FVA)
Description:
An orifice plate is a constriction device used in combination with a differential pressure transmitter to measure flow rate. Our orifice plates are designed according to JIS Z8762-1995 (ISO 5167-1: 1991)
FCX-AIII Series Level Transmitter (FKE-5)
Description:
Highly accurate level measurement
High accuracy: ±0.2%
Detector for sewage water available
Measures water level from 1.5 m to 50 m
Powerful built-in arrester
Water Level Transmitter (FQK)
Description:
Diaphragm material: Stainless steel 316L, hastelloy-C, monel, tantalum, titanium, zirconium, gold-plated stainless steel 316L
Accuracy rating (for spans greater than 10% of URL): ±0.2%
Output signal: 4–20 mA DC
Power supply voltage: 10.5–45 V DC (non-explosion-proof version)
Elevation/suppression: -100% to +100% of URL
Enclosure: IEC IP67, NEMA6/6p
Ex-proof approvals: TIIS, FM, CSA, ATEX, IECEx
Ambient temperature: -40°C to +85°C (non-explosion-proof version)
Digital Temperature Controllers (PXF)
Description:
Precise control
Easy-to-see display
Practical options
Most compact class in industry
Universal input
Digital Temperature Controllers (PXR3)
Description:
*PXR4, PXR5, PXR7, and PXR9 were discontinued and replaced by PXF series.
Versatile model with easy-to-see LED, transfer output, communication function, and more.
Digital Temperature Controllers (PXE)
Description:
Simple and compact
New design: 1.6-mm thick, world's thinnest front panel
Shallow depth: 62 mm
Input type and measuring range are programmable
A user can switch input type among Pt100 and thermocouples and their measuring range with front keys
Flexible:Up to two alarm outputs
Front waterproof structure (IP66)
Flexible:
On-off, PID, fuzzy, two-degree-of-freedom PID control
Auto tuning is available except for on-off control.
Heating and cooling dual control available
Relay contact output or SSR drive output
Digital Controllers (PXH)
Description:
High speed and high accuracy
High speed control: 50 ms input sampling
Indication accuracy: 0.1%
5-digit display can show 0.01°C
Accepts various input: thermocouple, RTD, voltage, or current
9 DIs, 9 DOs, and 2 AOs
Variety of functions: RS-485, T-Link, math function, ramp soak, transmitter power supply, complete templates
Shallow body and front waterproof structure
Easy parameter setting thanks to the loader software
Module Type Temperature Controllers (PUM Series)
Description:
Temperature controller and PLC are incorporated into single controller. Smart! User friendly! Fast!
Efficient solution that meets your expectations. Parameter loader software facilitates the parameter setting and the control status check.
Digital Thermostat (PXR3)
Description:
Temperature alarm with on/off contact output, DIN 24 x 48 mm size. Suited for overheat detection of thermocouples or thermistors used in machines or equipment.
Accepts thermocouple input or thermistor input
Allows you to quickly check alarm setpoint and process value
Front waterproof structure equivalent to NEMA-4X standard
Two relay-contact outputs available optionally
Optional DIN rail mounting adapter allows rail-mount or wall-mount
UL and C-UL certified
Paperless Recorders (PHF)
Description:
Compact front panel: 144 x 160 mm. Up to 6 channels for thermocouples, RTD, voltage, or current input
Data saving on CompactFlash
Data viewer and parameter loader software provided as standard
Ethernet (option)
Lithium-ion battery driven version available
Quick search and display of past data
3 or 6 input channels
Paperless Recorder (PHR)
Description:
Provides flexibility and variety in the handling of record data. Up to 9 or 18 channels for thermocouples, RTD, voltage, or current input
Wide variety of display mode
Large-capacity data storage
Easy operation with on-screen guidance
Data viewer and parameter loader software provided as standard
Compact design: 160 x 144 x 185 mm, 1.5 kg
RS485 (MODBUS) (option)
Ethernet (option)
Paperless Recorder (PHL)
Description:
Provides flexibility and variety in the handling of record data. Up to 9 or 18 channels for thermocouples, RTD, voltage, or current input
Wide variety of display mode
Large-capacity data storage
Data viewer and parameter loader software provided as standard
Compact design: 160 x 144 x 185 mm, 1.5 kg
RS485 (MODBUS) (option)
Ethernet (option)
Paperless Recorder (PHU)
Description:
Large size paperless recorder. Front panel 300 x 300 mm. Up to 36 channels for thermocouples, RTD, voltage, or current input
Data saving on CompactFlash
Data viewer and parameter loader software provided as standard
Ethernet (option)
Quick search and display of past data
9, 18, 27, or 36 input channels